EMC-compliant layout: test plan, lab support, corrective measures
Immunity and radiated emissions, the two sides of electromagnetic compatibility (EMC), are designed in from the first trace at MHD. The EMC-compliant layout is joined by the test plan for the laboratory, support during the measurement and, if a limit is exceeded, the corrective measure. Which is why a retest is rarely needed.
Drawing up the EMC test plan: standards, test severity levels, set-up, operating states
The test plan comes before the lab appointment. It defines which standards apply, at which test severity level measurements are taken, what the test set-up looks like and in which operating states the device runs during the test. The laboratory receives a document it can work by. You know before the measurement what is being tested and why.
Which standards apply is settled by the project's regulatory requirements, such as IEC 60601 in medical technology or IEC 62368, each with its associated EMC limits. From this comes the list of applicable standards with their design consequences; the EMC test plan follows on from it. It can be commissioned on its own, including to prepare the EMC test for a layout designed in-house.
- Standards: which standards and EMC limits apply to your product
- Test severity level: how severely immunity and emissions are tested
- Set-up and operating states: the test set-up and the operating states in which measurements are taken
EMC-compliant layout from the first trace
Whether a device stays within its limits is decided at placement, routing and power supply. Noise sources and sensitive areas are placed apart, return current paths under fast signals stay closed, decoupling capacitors sit according to function, current loops at filters and power supply stages stay small. These decisions are made in Step 03 of the MHD process, the PCB layout.
The basis for this is certified training: the seminar on EMC assembly design from ZED IV (Zertifizierter Elektronik-Designer, the FED's certified electronics designer programme) and the EMC Designer training at the VDI (Association of German Engineers). Added to that is experience from measurement electronics and scientific instrumentation with low-noise analogue stages.
- Grounding scheme and return current paths: continuous reference planes under fast signals so that every return current path stays closed
- Power supply: small current loops at filters and power supply stages, decoupling capacitors placed according to function
- Placement and routing: noise sources and sensitive areas kept apart, crossing traces avoided, via fencing where needed
Lab support and corrective measures
On the test day, MHD supports the measurement. Emissions and immunity are run to the test plan, for immunity ESD, surge and burst among others. If a limit is exceeded, the cause is narrowed down and the corrective measure defined. You receive the test report with the measured values and, where necessary, the changes implemented.
If a retest becomes necessary, MHD knows the set-up, operating states and measurement data from the first run and supports the retest as well.
- Emissions: radiated emissions measured against the limits from the test plan
- Immunity: ESD, surge and burst in the defined operating states
- Corrective measure: cause narrowed down, change implemented in the design, documented in the design file
EMC consultancy for electronics designed in-house
EMC consultancy also applies to a design from your own house: as a check of layer stack-up, grounding scheme and placement before the first lab appointment, or as a review after a failed test. You receive findings and recommended corrective measures documented to a depth that satisfies purchasing, quality assurance and audit. The entry point for this is the independent design review.
The EMC-relevant design decisions are taken by Dr Häuser. For volume and peak load we work with the partner network, under the same specifications, reviews and releases.
The outcome
The outcome is a set of documents that the laboratory, quality assurance and approval can work with. They live in the design file, so months later, the reasoning behind every decision is still on record.
- Test plan for the laboratory with standards, test severity levels, set-up and operating states
- Test report from the lab support
- In case of a fail, the corrective measures implemented, documented
EMC at MHD: test plan, lab support and corrective measures
The questions that come up most often in initial consultations about this service.
Can you draw up the EMC test plan for a layout that was designed in-house?
Yes, the test plan can be commissioned on its own. MHD needs the applicable standards, or the product environment they follow from, plus the set-up and operating states of the device. The laboratory receives a document to run the measurement by.
Our device has failed the EMC test. What happens next?
The test report and layout data come to MHD. From the measured values, the cause is narrowed down and the corrective measure defined, documented to a depth that satisfies quality assurance and audit. On request MHD implements the change in the layout and supports the retest.
Which standards feed into the EMC test plan?
Those from your project's regulatory requirements, such as IEC 60601 in medical technology or IEC 62368, each with its associated EMC limits. Clearance and creepage distances to IEC 60664 belong in the project's list of applicable standards, which MHD draws up as part of the regulatory work; the EMC test plan follows on from it.
Are you present at the lab appointment?
Yes. Support in the laboratory is part of the service. The EMC training at the VDI covers the measurement techniques for emissions and immunity; added to that is experience from measurement electronics and scientific instrumentation.
How do you recognise an EMC-compliant PCB design?
By its grounding scheme, power supply and placement. Reference planes run continuously under fast signals, current loops at filters stay small, decoupling capacitors sit according to function, noise sources and sensitive areas are kept apart. MHD checks these points on an in-house layout of yours as well.
EMC belongs at the start of the project.
Describe product, regulatory environment and deadline, and you'll receive an initial assessment of test plan and lab support.